Fiber Optic
Fibre carries data as pulses of light instead of electricity. That one change buys enormous distance, near-unlimited bandwidth, complete immunity to electrical interference, and a cable that is genuinely hard to tap. This lesson covers the physics that makes it work, the two fibre modes and their exact core sizes, the connectors you must recognise, and when fibre beats copper.
Light as the medium
An optical fibre is a thin strand of ultra-pure glass (or plastic) surrounded by layers that keep light trapped inside it. A transmitter converts electrical bits into rapid pulses of light; a photodetector at the far end converts the light back into electricity. Because the signal is light, it is not affected by the electrical noise that plagues copper, and it can travel much farther before it needs to be regenerated.
A fibre has two main parts:
- Core — the central glass strand that actually carries the light. Its diameter is the number that distinguishes single-mode from multimode fibre.
- Cladding — the surrounding glass layer with a lower refractive index (it bends light less) than the core. Cladding is what traps the light in the core. It is normally 125 µm across for both fibre types.
Around that sits a protective buffer coating, then strength members and an outer jacket. The glass itself is drawn so pure that light can travel for kilometres with only small loss.
Signal
Pulses of light, not voltage. The transmitter converts bits into light and a photodetector converts light back into bits.
Core
~9 µm (single-mode) or 50 / 62.5 µm (multimode). The number that decides the mode.
Cladding
125 µm for every type, with a lower refractive index than the core so light cannot escape.
Total internal reflection
Fibre does not have a mirror inside it. It guides light using a phenomenon called total internal reflection (TIR). Light travels more slowly in a dense medium (the core) than in a less dense one (the cladding) because the core has a higher refractive index. When a light ray inside the core strikes the core–cladding boundary at a shallow angle — steeper than the critical angle measured from the boundary — it is reflected straight back into the core instead of escaping.
If the ray is too steep (too close to the centre line) it still reflects, but a ray that hits the boundary at too shallow an angle would escape — those rays are why fibre has a limited acceptance angle for how much light can be launched into it. Everything that enters within that angle will be carried.
Single-mode vs multimode
There are exactly two families of fibre, and the difference comes down to the size of the core and the light source used. Learn these numbers; they are exam favourites.
| Property | Single-mode (SMF) | Multimode (MMF) |
|---|---|---|
| Core diameter | about 9 µm (roughly 8–10) | 50 µm or 62.5 µm |
| Cladding | 125 µm | 125 µm |
| Light source | Laser (narrow, single wavelength) | LED or VCSEL |
| Number of light paths | One mode | Many modes |
| Typical distance | Long haul — tens of kilometres (10 km and beyond) | Short haul — typically up to about 550 m depending on variant and speed |
| Cost | Higher (laser optics) | Lower (LED/VCSEL optics) |
| Typical use | WAN, ISP backbone, long campus runs, data-centre interconnects | Within a building, campus backbone, data-centre racks |
Attenuation, dispersion, and no crosstalk
Three terms describe how fibre behaves over distance:
- Attenuation — the gradual loss of signal strength as light travels, caused by absorption and scattering in the glass. It is far lower than on copper, which is exactly why fibre spans kilometres. It is measured in decibels per kilometre (dB/km), and optical links are budgeted so enough power arrives at the receiver.
- Dispersion — the spreading of light pulses as they travel. In multimode fibre, different rays take different path lengths and arrive at slightly different times (modal dispersion); in single-mode fibre, different wavelengths travel at slightly different speeds (chromatic dispersion). Dispersion smears pulses together and limits how fast you can signal and how far you can go before needing regeneration.
- Crosstalk-free — because light is confined inside the core, one fibre cannot induce a signal in another. Fibre has essentially zero crosstalk and is also immune to EMI, unlike copper.
Attenuation
Gradual loss of signal strength, measured in dB/km. Far lower than copper, which is why fibre spans kilometres.
Dispersion
Pulse spreading over distance: modal in multimode, chromatic in single-mode. It limits both speed and reach.
No crosstalk
Light stays inside the core, so one fibre cannot induce a signal in another — and it is immune to EMI.
Optical connectors: LC, SC, ST, FC
Four connector types appear in course material. Recognise each by shape and locking method:
| Connector | Shape / locking | Status |
|---|---|---|
| LC | Small form factor, 1.25 mm ferrule, uses a small clip; usually supplied as a duplex pair | Modern and dominant in data centres and SFP modules |
| SC | Square body, push-pull “stick and click”, 2.5 mm ferrule | Very common; older than LC but still widely deployed |
| ST | Round body with a bayonet twist-lock | Legacy; older campus and fibre-to-the-desk installations |
| FC | Round body with a screw-on coupling, 2.5 mm ferrule | Legacy; common in telecoms and test equipment |
Why fibre wins
Fibre beats copper on four fronts that the exam likes to test:
- Distance — copper Ethernet is limited to 100 m over UTP; fibre runs from hundreds of metres (MMF) to tens of kilometres (SMF) without a repeater.
- Bandwidth — light has an enormous usable frequency range, so fibre carries far higher data rates (10, 40, 100 Gbps and beyond) than copper over the same span.
- No EMI — light is unaffected by electrical noise, motors, or radio sources, so fibre works in electrically hostile places and leaks no signal of its own.
- Tap-resistant — signals do not radiate from a fibre the way they do from copper, so intercepting traffic requires physically cutting or bending the fibre. This makes fibre the medium of choice for secure backbones.
Fibre vs copper
| Characteristic | Fibre optic | Twisted-pair copper |
|---|---|---|
| Signal carried | Pulses of light | Electrical voltage |
| Max distance | Up to tens of km (SMF); ~550 m (MMF) | 100 m (Ethernet UTP) |
| Bandwidth | Very high (10–100 Gbps+) | Lower (typically 1–10 Gbps) |
| EMI immunity | Total — unaffected | Susceptible; needs twisting/shielding |
| Crosstalk | None | Present; reduced by twisting |
| Security / tapping | Hard to tap | Easier to tap; radiates signal |
| Cost & termination | More expensive, skilled to terminate | Cheap, easy to terminate |
Review
Check what you have learned with these review questions.
Sources & references
- IEEE. IEEE 802.3 (Ethernet; fibre-optic PHYs including 1000BASE-SX/LX and 10GBASE-SR/LR). standards.ieee.org.
- ISO/IEC. ISO/IEC 11801 and ANSI/TIA-568 — optical fibre cabling classes (OM1–OM5, OS1/OS2). tiaonline.org.
- Cisco. CCNA (200-301) Exam Topics — Network Fundamentals (network media). cisco.com.
- Cisco. CCNA: Introduction to Networks — “Network Media” (fibre types, connectors, and properties). netacad.com.
Target exams: CCNA 200-301 v1.1 · CyberOps Associate 200-201. Last content verification: 2026-10-11.