Week 4 · Lesson 7

Connection Types and Power over Ethernet

Not every link is built the same way. Some connect exactly two devices and give them the whole wire; others let a crowd share the medium and take turns. This lesson draws that distinction, tours the four physical connection types you have now met, and then shows how the same Ethernet cable that carries data can also carry electricity — Power over Ethernet, the reason a ceiling access point or desk phone needs no mains socket.

CCNA 200-301 Domain 1.0 Network Fundamentals Verified 2026-10-11
Part 1

Shared versus dedicated connections

The first question you can ask about any physical link is simple: how many devices share it, and do they have to take turns? The answer sorts every connection into one of two families.

A dedicated connection — also called a point-to-point link — connects exactly two devices, and the two share all the capacity of the medium between them. When your PC plugs into a switch port, that segment has your PC at one end and the switch at the other; nobody else transmits on it. Because only one device transmits in each direction, a dedicated link can run full duplex, sending and receiving simultaneously without any contention.

A shared connection — a multi-access or broadcast medium — is used by several devices at once, and they must arbitrate who speaks. Classic thin/thick coaxial Ethernet and old Ethernet hubs put many devices on one electrical segment; modern Wi-Fi puts every client in range on one radio channel. Shared media are cheap and simple, but the bandwidth must be divided, and the devices need a rule to avoid talking over one another. Wired shared media use CSMA/CD (carrier sense multiple access with collision detection); wireless uses the collision-avoidance variant, CSMA/CA.

Definition — connection type. The connection type describes the physical and logical arrangement of a link: whether it is a dedicated point-to-point path between two devices, or a shared multi-access path used by several. The choice decides whether the link can run full duplex and how it handles contention.

The important nuance, and a common source of confusion, is that a switch creates many small point-to-point links while the switch as a whole still serves a shared logical network. Each cable from a host to the switch is dedicated; but all those hosts sit in the same broadcast domain and still share the aggregate capacity of the switch’s uplinks. So “dedicated” describes the individual wire, not the whole LAN.

Dedicated or shared? · pick a link

Part 2

Half duplex and full duplex

Duplex is the direction rule for a link.

Because full-duplex links do not share the wire, collisions are impossible on them and CSMA/CD is switched off. That is why a healthy modern Ethernet port should report zero collisions — a fact you will lean on hard in Lesson 8, when collisions and late collisions become the signature of a duplex mismatch.

Note. A switch port to a host is point-to-point and full duplex. A port connected to an old hub, or a wireless client sharing a channel, is half duplex and shared. If you see the word “hub” in a scenario, expect a shared, half-duplex link and collisions.
Part 3

The four connection types

You met the media individually earlier in the week; here they are as connection types, with the trade-offs that decide which one a designer reaches for.

TypeMediumTypical reachBest for
Ethernet (IEEE 802.3)Copper twisted pair (UTP/STP), RJ45Up to 100 mLAN edge: PCs, phones, APs, cameras; the default access link
Fibre opticGlass/plastic strand, lightHundreds of metres to many kilometresBackbones, building-to-building, high EMI areas, long runs
CoaxialSingle copper core in a shieldVaries; often hundreds of metresCable broadband (DOCSIS), older Ethernet (10BASE2/5)
Wi-Fi (IEEE 802.11)Radio (2.4/5/6 GHz)Tens of metres indoorsMobility: laptops, phones, tablets, IoT

Ethernet over twisted pair is the workhorse of the wired LAN. Its 100 metre limit, its cheapness, and its support for Power over Ethernet make it the natural access connection. Fibre trades cost and complexity for enormous distance and total immunity to electromagnetic interference; it is the standard choice for the links between switches and buildings. Coaxial survives today mainly as the medium your cable modem uses. Wi-Fi is the only connection type that is fully shared at the physical layer, and it is chosen whenever users must be free to move.

Exam tip. The four connection types map to four different problems. Ethernet = the access edge, up to 100 m. Fibre = the backbone, hundreds of metres to kilometres, and immune to EMI. Coaxial = the cable-modem drop. Wi-Fi = mobility, and the only one that is shared at the physical layer.
Part 4

What Power over Ethernet is

Power over Ethernet (PoE) delivers direct-current electrical power and Ethernet data over the same twisted-pair cable. It exists because the devices we hang in awkward places — a wireless access point on a ceiling, a camera on an eave, a phone on a desk — are exactly the devices for which running a separate electrical socket is expensive or impossible. PoE means the installer runs one cable and both jobs are done.

Two roles define every PoE link:

Power is injected using what engineers call phantom power: the DC voltage rides on the same wires as the data without disturbing the signal. There are two wiring schemes. Alternative A uses the same pairs that carry the data (pins 1–2 and 3–6), so the power and data share conductors via centre taps. Alternative B uses the unused spare pairs (pins 4–5 and 7–8). Devices negotiate which scheme to use automatically. In endspan deployment the switch itself is the PSE; in midspan deployment a separate injector sits mid-cable.

Tip. A PD must never receive power it did not ask for. The PSE first applies a low voltage and looks for a detection signature (about 25 kΩ); only a genuine PD presents it. Then the PSE performs classification to learn how much power the device wants, and supplies only that amount. This handshake is why you can plug an ordinary laptop into a PoE port without frying it — the laptop presents no signature and is simply powered up as a normal data link.
The PoE handshake · step through the sequence
1 of 4

Part 5

PoE standards: af, at, and bt

The IEEE has published three generations of PoE, each raising the power ceiling. Learn the tiers and their headline numbers — they are fair game on the exam.

StandardMarketing namePSE port powerPower at the PDPairs used
IEEE 802.3afPoEup to 15.4 Wabout 12.95 W2 pairs
IEEE 802.3atPoE+up to 30 Wabout 25.5 W2 pairs
IEEE 802.3bt (Type 3)PoE++ / 4PPoEup to 60 Wabout 51 W4 pairs
IEEE 802.3bt (Type 4)PoE++ / 4PPoEup to 90 Wabout 71.3 W4 pairs

Notice that the power at the PD is always lower than the power at the PSE port: some energy is lost as heat in the cable itself, and the longer the cable, the greater the loss. That gap is why the standards quote two figures. 802.3af comfortably runs a basic IP phone or a legacy access point. 802.3at (PoE+) was created for devices such as dual-radio wireless access points and pan-tilt-zoom cameras. 802.3bt uses all four pairs to push even harder, powering high-end APs, video displays, PoE lighting, and thin clients.

Exam tip. Anchor the trio with a single line: 802.3af = 15.4 W (PoE), 802.3at = 30 W (PoE+), 802.3bt = 60 W/90 W (PoE++). If a question says “a device needs about 25 watts”, 802.3af is too small and the answer is 802.3at. If it says “up to 90 W”, that is 802.3bt Type 4.
PoE tier decoder · select a standard

Part 6

Power budgets, classes, and where PoE is used

A PoE switch cannot give every port its maximum indefinitely; it has a finite power budget set by its power supply. A 24-port switch with a 370 W budget, for example, cannot run 24 ports at 30 W (that would need 720 W). The switch therefore reserves power per port according to the device’s class and refuses to power up a port if the budget is exhausted. This is a real design constraint: an under-budgeted switch may simply refuse to power the last few access points.

ClassTypical deviceReserved at port
Class 0Default / unclassified15.4 W
Class 1Very low power4 W
Class 2Low power7 W
Class 3Typical phone, basic AP15.4 W
Class 4PoE+ device30 W
Class 5–8802.3bt high-power devicesUp to 90 W

Negotiation happens in two steps. Hardware classification uses the electrical signature and a class resistor, working down to the device even before it boots. Finer-grained negotiation — down to fractions of a watt — uses LLDP or CDP, the Layer 2 discovery protocols, to carry a power request and grant. The 802.3bt amendment adds Autoclass, which measures actual consumption so the switch can hand unused power back to the budget.

Watch out. Two traps live here. First, mixing standards: an 802.3af PSE can power an 802.3at PD only if the device can fall back to the lower power — otherwise it will not come up, or will reboot repeatedly. Second, passive PoE injectors that force power onto the cable without negotiation can damage a device that does not expect it. Always match the PSE’s standard to the PD’s requirement.

Where PoE is used

PoE is everywhere a small, network-connected device would otherwise need a power outlet in a difficult spot:

The design payoff is practical: one cable per device, one place to manage power (the switch), and the ability to remotely power-cycle a locked-up access point by bouncing its port. The design cost is that the switch’s power budget, not just its port count, becomes a planning number.

Switch power budget · build a PoE design
0 Wneeded

Part 7 · Your turn

Review

Check what you have learned with these review questions.

Review · 6 questions

Sources

Sources & references

  1. IEEE. IEEE 802.3: Ethernet, including Clause 33 (802.3af), 802.3at, and 802.3bt Power over Ethernet amendments. standards.ieee.org.
  2. Cisco. Power over Ethernet (PoE) Configuration Guide (PSE/PD roles, classes, budgets, and negotiation). cisco.com.
  3. Cisco. CCNA (200-301) Exam Topics, Network Fundamentals — physical interfaces and cabling. cisco.com.
  4. Cisco. CCNA: Introduction to Networks — “Network Media” and “Physical Layer” (connection types and PoE). netacad.com.

Target exams: CCNA 200-301 v1.1 · CyberOps Associate 200-201. Last content verification: 2026-10-11.